BENEFITS

Why physicians choose CAAS vFFR

Proven Outcomes

FAST III confirms vFFR is non-inferior to FFR.

Simple & Reproducible

Robust automated algorithm.

FAST cath lab workflow

5x FASTer than FFR.

Improved patient comfort

No wire and hyperemic agent, less radiation exposure and contrast.

Faster procedures. Wire-Free. Similar outcome.

5x

Faster than FFR [2]

~40%

Reduction in intraprocedural complications vs FFR

Non-inferior

to FFR [1]

R=0.95

Correlation between observers [4]

vFFR
Pullback

ABOUT

Functional Lesion Information

Based on just 2 standard angiograms and the patients aortic root pressure, vFFR builds a 3D reconstruction of the coronary artery and provides the functional lesion information.

3D Model and vFFR value

Anatomical lesion information

Use the anatomical lesion information to support treatment planning.

  • Lesion diameter
  • Obstruction length
  • Percentage stenosis
  • Reference diameter

Treatment Planning

  • Simulate effect of stent placement with Residual vFFR* [5].
  • Optimize treatment strategy with understanding contribution of multiple lesions*.
  • Ensure succesful revascularization and minimize future risks with post PCI vFFR assessment [6].

FAST III is an investigator-initiated study, sponsored by the European Cardiovascular Research Institute, and supported by research grants from Pie Medical Imaging and Siemens Healthineers. It is an open label, multicenter randomized trial comparing vFFR guided versus FFR guided coronary revascularization in patients with intermediate coronary lesions. The 1 year MACE defined as: the composite of all-cause death, any myorcardial infarction (MI), and any revascularization within one year after randomization.
Subjects
2235
Patients
Centers
37
Clinical end point
MACE at 1-year
follow up
The FAST II study was an international multi-center prospective trial in 6 countries (Netherlands, Germany, Italy, France, Unites States and Japan) evaluating the diagnostic accuracy to predict FFR ≤ 0.8 and reproducibility of vFFR in an in-hospital and off-line core laboratory setting.
Subjects
334
Patients
Diagnostic Accuracy (AUC)
0,93
Reproducibility (r)
0,87
between in-hospital and corelab
FAST I was a single center retrospective study evaluating the diagnostic accuracy to predict FFR ≤ 0.8 and reproducibility of vFFR.
Subjects
294
Patients
Diagnostic Accuracy (AUC)
0,94
Reproducibility (r)
0,95
between observers
Rotterdam, The Netherlands

"The results of FAST III confirm the safety and feasibility of the online use of vFFR as an easy to use minimally invasive tool to guide revascularization in patients with intermediate coronary artery lesions in need of physiological lesion assessment."

- Dr. Joost Daemen, MD, PhD, Erasmus Medical Center, Rotterdam, The Netherlands

Read more
Dr. Joost Daemen, MD, PhD
Bielsko-Biała, Poland

"The results of FAST III confirm the safety and feasibility of the online use of vFFR as an easy to use minimally invasive tool to guide revascularization in patients with intermediate coronary artery lesions in need of physiological lesion assessment."

- Dr. Krzysztof Milewski, MD, PhD, Cardiac Surgery Center in Bielsko-Biala, American Heart of Poland, Bielsko-Biała, Poland

Read more
Dr. Krzysztof Milewski, MD, PhD
Sydney, Australia

"Using Pie Medical Imaging software in our daily clinical routine significantly enhances our procedural planning and diagnostic confidence. The speed, accuracy, and reproducibility of the tools allow us to optimize patient care seamlessly."

- Dr. Daniel Akrawi, Campbelltown Hospital, Western Sydney University, Sydney, Australia

Read more
Dr. Daniel Akrawi

Clinical Evidence

vFFR Time

  • 225 Lesions
  • Diagnostic Accuracy: 0.92
  • ~ 14 min FASTer than wire-based FFR

LIPSIA-STRATEGY

vFFR vs FFR

  • 1053 Patients
  • MACE 3.0% CAAS vFFR vs 4.1% Wire-based FFR

vFFR Revascularization guidance - AIR STEMI

  • 1823 patients
  • Physiology-guided revascularization resulted in lower risk of primary-outcome event than a conventional angiography-guided revascularization (8.9% vs 13.7)

Key publications 

  • [1] Joost Daemen et al. Angiography-Based Physiology to Guide Coronary Revascularization, New England Journal of Medicine. 2026 doi:10.1056/NEJMoa2601841

    [2] D.Akrawi, et al., “VERMONT: Vessel Fractional Flow Reserve (vFFR) Assessment of Stenosis Severity: A Prospective Study,” Catheter Cardiovasc Interv. (2025)

    [3] Neleman et al. Extended Validation of Novel 3D Quantitative Coronary Angiography-Based Software to Calculate vFFR: The FAST I Study. JACC Cardiovasc Imaging. 2021

    [4] Masdjedi et al. Vessel fractional flow reserve (vFFR) for the assessment of stenosis severity: the FAST II study. EuroIntervention 2022

    [5] Tomaniak M, et. al. Diagnostic Accuracy of Coronary Angiography-Based Vessel Fractional Flow Reserve (vFFR) Virtual Stenting. J Clin Med. 2022

    [6] Masdjedi et al. Validation of novel 3‐dimensional quantitative coronary angiography-based software to calculate fractional flow reserve post stenting. Catheter Cardiovasc Interv. 2020

    [7] Masdjedi et al. Validation of 3-Dimensional Quantitative Coronary Angiography based software to calculate Fractional Flow Reserve: FAST Assessment of STenosis severity (FAST)-study. EuroIntervention 2019

* The regulatory approval status of CAAS Workstation or any of its features may vary per region. Please contact: regulatory@pie.nl to learn if clinical use of CAAS Workstation or any specific features is allowed in your region

OUR PILLARS

Why leading cardiac centers trust 
Pie Medical Imaging

Global leader in cardiac imaging

Exclusively dedicated to cardiovascular imaging, our deep domain expertise powers leading cardiac centers worldwide, delivering consistent, reproducible insights across clinical trials, guidelines, and daily practice.

Seamless workflow integration

We provide independent, vendor-agnostic software that fits effortlessly into existing hospital IT, PACS, and OEM ecosystems, focusing on cohesive, streamlined cardiac workflows rather than isolated tools.

Bridging clinics, IT and industry

Serving as a trusted partner for healthcare providers, IT departments, and device vendors, we unite clinical needs, technical requirements, and industry innovation into a single, unified cardiac imaging strategy.

Innovation-driven and clinically validated

Powered by a large in-house R&D team, proprietary algorithms, and decades of clinical collaboration, our technology undergoes continuous refinement.