Complete assessment of your MR 4D Flow data

CAAS MR 4D Flow is designed to extract relevant information from 4D Flow MRI images, within a few clicks. Two pioneering 4D Flow modules facilitate a complete flow analysis that can aid in reading and interpreting cardiovascular MR images and assist in planning the time and type of an intervention. The large-vessel analysis module for the aorta and major arterial branches (CAAS MR 4D Artery) including wall shear stress assessment, and theacardiac analysis module for the assessment of heart valve function, regurgitation, and intra-cardiac flow dynamics (CAAS MR 4D Heart).

BENEFITS

Why physicians choose CAAS 4D Flow

Simple and reproducible




Robust automated measurements and analysis.

Vendor
neutral




Standardize multi-vendor data on one single platform.

Validated accurate performance



Accurate performance validated in multiple scientific studies

One dataset, the whole picture



Conduct all complex measurements from one single dataset.

Visualize complex anatomy and function

  • Intuitive and instant 3D anatomy and blood flow visualization.
  • Freedom to retrospectively explore any region of interest.
  • Freedom to retrospectively explore any region of interest.
  • Advanced hemodynamic mapping including wall shear stress and pressure difference*.

Advanced quantification. Deeper clinical insights

  • Extract comprehensive 4D flow measurements
  • Analyze new clinical parameters without repeat acquisition
  • Leverage automated valve tracking for fast and reproducible valve assessment
  • Gain deeper insight with advanced flow, regurgitation, pressure gradient, and wall shear stress analysis

* The Wall Shear Stress Analysis and Pressure Difference Analysis are not 510(k) cleared and therefore not meant for clinical decision making.

TESTIMONIALS

What customers say about CAAS MR 4D Flow 

Leeds, UK

"The CAAS analysis tool makes 4D flow MRI analysis quick and straight forward. The valve tracking option is intuitive. Its flexibility allows analysis of even the most complex congenital heart disease.x"

- Malenka Bissell, MD, PhD (University of Leeds, UK)

Read more
Malenka Bissell, MD
Brussels, Belgium

"At ULB - together with ESA, NASA and the DLR - we study the cardiovascular deconditioning induced by spaceflights. The comprehensible workflows of Caas MR Solutions 4D Flow helps us to understand arterial and intra-cardiac flow in volunteers and astronauts/cosmonauts."

- Dr. Jérémy Rabineau, Université Libre de Bruxelles, Belgium, Brussels, Belgium

Read more
Dr. Jérémy Rabineau
OUR PILLARS

Why leading cardiac centers trust 
Pie Medical Imaging

Global leader in cardiac imaging

Exclusively dedicated to cardiovascular imaging, our deep domain expertise powers leading cardiac centers worldwide, delivering consistent, reproducible insights across clinical trials, guidelines, and daily practice.

Seamless workflow integration

We provide independent, vendor-agnostic software that fits effortlessly into existing hospital IT, PACS, and OEM ecosystems, focusing on cohesive, streamlined cardiac workflows rather than isolated tools.

Bridging clinics, IT and industry

Serving as a trusted partner for healthcare providers, IT departments, and device vendors, we unite clinical needs, technical requirements, and industry innovation into a single, unified cardiac imaging strategy.

Innovation‑driven and clinically validated

Powered by a large in-house R&D team, proprietary algorithms, and decades of clinical collaboration, our technology undergoes continuous refinement.

Key publications

Congenital 4D Flow: fetal/neonatal/children

  • Zamani-Aliabadi et al. – 2024 - Assessment of 4D flow MRI for quantification of left-to-right shunt in pediatric patients with ventricular septal defect: comparison with right heart catheterization. Front. Cardiovasc. Med. 11:1399110. doi: 10.3389/fcvm.2024.1399110. Available from: https://doi.org/10.3389/fcvm.2024.1399110

  • Sjöberg P, et al. Comparison of 2D and 4D Flow MRI in Neonates Without General Anesthesia. J Magn Reson Imaging. 2023 Jan;57(1):71-82. doi: 10.1002/jmri.28303. Available from: https://pmc.ncbi.nlm.nih.gov/articles/PMC10084310/pdf/JMRI-57-71.pdf 

Valve Tracking

  • Kamphuis VP, Roest AAW, Marsan NA, van den Boogaard PJ, Kroft LJM, Aben JP, et al. Automated cardiac valve tracking for flow quantification with four-dimensional flow MRI. Radiology [Internet]. 2019 Jan 30 [cited 2019 Jul 8];290(1):70–8. Available from: http://pubs.rsna.org/doi/10.1148/radiol.2018180807 

  • Garg P, Swift AJ, Zhong L, Carlhäll C-J, Ebbers T, Westenberg J, et al. Assessment of mitral valve regurgitation by cardiovascular magnetic resonance imaging. Nature Reviews Cardiology [Internet]. 2019 Dec 9 [cited 2019 Dec 19];1–15. Available from: http://www.nature.com/articles/s41569-019-0305-z

4D Flow Validation

  • Adriaans BP, Westenberg JJM, Cauteren YJM, Gerretsen S, Elbaz MSM, Bekkers SCAM, et al. Clinical assessment of aortic valve stenosis: Comparison between 4D flow MRI and transthoracic echocardiography. Journal of Magnetic Resonance Imaging [Internet]. 2020 Feb 30 [cited 2020 Apr 2];51(2):472–80.  Available from: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26847

  • Grafton-Clarke C, Njoku P, Aben J-P, et al. Validation of aortic valve pressure gradient quantification using semi-automated 4D flow CMR pipeline. BMC Res Notes. 2022;15(1):151. Available from doi:10.1186/S13104-022-06033-Z

Wall Shear Stress Analysis 

  • van der Palen, R.L.F., Roest, A.A.W. et al. Scan–rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers. Magn Reson Mater Phy (2018). DOI: https://doi.org/10.1007/s10334-018-0688-6. 

  • Perinajová R, Juffermans JF, Mercado JL, et al. Assessment of turbulent blood flow and wall shear stress in aortic coarctation using image-based simulations. Biomed Eng Online. 2021;20(1). Available from doi:10.1186/S12938-021-00921-4 

  • Farag ES, Vendrik J, van Ooij P, Poortvliet QL, van Kesteren F, Wollersheim LW, et al. Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls. European Radiology [Internet]. 2019 Mar 21 [cited 20 Apr 2];29(3):1444–51. Available from: http://link.springer.com/10.1007/s00330-018-5672-z

Cerebrospinal fluid

  • Wåhlin et al - 2021 -  4D flow MRI hemodynamic biomarkers for cerebrovascular diseases. J Intern Med. 2022;291:115–127. Available from: https://onlinelibrary.wiley.com/doi/full/10.1111/joim.13392 


    Discusses 4D flow MRI approaches for analyzing the cerebral vasculature and key hemodynamic biomarkers that can be reliably assessed using the technique. Additionally highlightcerebrovascular diseases where one or multiple hemodynamic biomarkers are of central interest.

  • Rivera-Rivera et al - 2024 - Four-dimensional flow MRI for quantitative assessment of cerebrospinal fluid dynamics Status and opportunities. NMR Biomed. 2024 July ; 37(7): e5082. Available from: https://doi.org/10.1002/nbm.5082 


    A review of the state of 4D CSF flow including challenges, novel proposed solutions, examples of clinical and research applications.

Case example Dynamic velocity tracking

  • Sawh et al - 2025 - Dynamic Velocity Tracking in the Left‐Ventricular Outflow Track Using Four‐Dimensional 4D Flow for the Assessment of Left Ventricular Outflow Track Obstruction. Clinical Case Reports, 2025; 13:e70465 Available from: https://doi.org/10.1002/ccr3.70465 


    This case describes the clinical value of stress 4D flow CMR as a novel, non- invasive modality for the comprehensive assessment of suspected LVOT obstruction. 

  • Assadi et al - 2024 - Clinical relevance of aortic conduit and reservoir function. Open Heart 

    2024;11:e002713. Available from: https://openheart.bmj.com/content/openhrt/11/2/e002713.full.pdf 


    This study shows that four-dimensional flow cardiovascular magnetic resonance (CMR) can directly measure aortic conduit and reservoir functions.

* The regulatory approval status of CAAS MR Solutions or any of its features may vary per region. Please contact: regulatory@pie.nl to learn if clinical use of CAAS MR Solutions or any specific features is allowed in your region.